| Product classification
> Mag, Vortex flowmeter & etc >
Vortex flowmeter
|
| VFM-8000
Series |

|
|
|
|
|
|
|
| No
|
Model
Name
|
PDF
Download
|
| Catalog
| English
Operating Manual
|
| 1
| Vortex flowmeter
(VFM-8000 Series) |
Download
[559.0 KB] | Download
[485.0 KB] | Download
[483.0 KB] |
|
|
|
| |
|
|
Product
Feature
|
•
The Ratio
is big, the accuracy is high and the press drop is few, the
medium popular use characteristic is good.
•
There is
pulse signal output and it is possible to connect at
computer and use it. •
Sensing
parts vortex shedder body and separation saddle.
•
The
inside high temperature piezo crystal does not contact
measurement medium, so the flow meter
structure
is simple, the popular use characteristic is good and the
stability is high. •
It will
be able to use various gas and the liquid Steam flow rate
inspection and calculation. •
Using
together computer, temperature, pressure and the density
sensor, high precision mass flow rate
or
it will be able to create a calorie flow rate inspection
weighting system.
|
|
|
|
| |
|
|
Product
Application
|
•
Gas
measurement at LNG yard •
Air
conditioning steam measurement
•
Energy
measurement in the cleanings and drying processes of
assemblies
|
|
|
|
| |
|
|
Product
Description
|
The
operation of the VFM 8000 is based on the Karman Vortex
Street. Vortices are formed as the fluid
flows around the shedder body which are alternately shed
from its sides. The flow causes these
vortices to be released forming a vortex street (Karman
Vortex Street), see Fig.2.
|
|
|
|